Controls

Expert Controller

191-EXPERTWW ADVANCED CONTROLLER

191-EXPERTII ADVANCED CONTROLLER

  • Ventilation based on static pressure and temperature
  • Two timed curtain output for tunnel ventilation
  • Up to 36 relay outputs for fan, heaters, misting, soaking, cooling, stir fan and time clocks
  • Manual override switches, indicator lights and relays for each stage
  • Feeder and heater run times and water monitoring are saved in memory for the current day and for the previous 75 days
  • Upload and download chip to easily transfer all the control settings from one controller to another controller (15 different programs can be set on chip)
  • Up to two air inlet outputs, two natural curtain outputs and two tunnel outputs
  • Energy saver features
  • Seamless ventilation steps between stages
  • PC programmable (optional)
Expert Controller Image

CLIMATE CONTROLLER TABLE

Expert series Products & features

Expert Controller Image 2
MPV 10 amp variable speed booster control (for controls w/1 var. speed)
MPVV 20 amp variable speed booster control (for controls w/2 var. stages)
MPV-010 10 amp slave module for expert controls
PF-6 Potentiometer feedback control w/display (must be used w/a TC-4 or TC5 series control
HM-10 10 amp variable control for heat mats or lamps w/display
TC1-C Variable speed control without display
6607-8046 Var-O-Matic manual variable speed control
TC1-1SD Single stage on-off control with display
TC4-4SD 4 stage on-off control with display
TC4-1V2S 1 variable, 2 on-off stages with display
TC4-1V3S 1 variable, 3 on-off stages with display
TC1-NV Natural ventilation control, with 1 on-off stage
TC4-NVS Natural ventilation control, with display and 2 on-off stages
TC5-3N3SA Natural ventilation control, 1 chimney, 2 natural curtain, 1 mist, 2 heat, alarm, display
TC5-8SDA* 8 stage on-off, alarm stage, display, humidity probe optional
TC5-12SDA* 12 on-off stages, alarm stage, display, humidity probe optional

TC5-1V6SA* 1 var., 6 on-off stages, alarm stage, display, humidity probe optional
TC5-1V10SA 1 var., 10 on-off stages, alarm stage, display, humidity probe optional
TC5-2V2SA* 2 var., 2 on-off stages, alarm stage, display, humidity probe optional
TC5-2V4SA* 2 var., 4 on-off stages, alarm stage, display, humidity probe optional
TC5-2V8SA* 2 var., 8 on-off stages, alarm stage, display, humidity probe optional
TC5-1N4FIA Power natural ventilation control, 1 var., 1 on-off, 1 curtain, 1 mist, 1 heat, alarm stage, display, humidity probe optional
TC5-1N5FIAB Power natural ventilation control, 1 var., 1 or 2 on-off stages, 1 curtain, 1 mist, 2 heat zones or cascade, alarm stage, display, humidity probe optional
TC5-1N8FA Power natural ventilation control, 1 var., 1 on-off, 1 curtain, 1 mist, 1 heat, alarm stage, display, humidity probe optional
TC5-2N6FA Power natural ventilation control, 2 var., 2 on-off stages, 2 curtain, 1 mist/heat, 2 heat-zones or cascade, alarm, display, humidity probe optional
TC5-T1A 11 stage power/natural/tunnel control, 1 var. alarm stage, display, humidity probe optional
TC5-T6A* 11 stage power/natural/tunnel control, alarm stage, display, humidity probe optional
TC5-ITA Timed inlet control with alarm

* 50 Hz Model Available

expert ii expert WW expert VP-18 expert Vt110 expert Pn110 expert natural exp-2V2SA exp-2V3SA exp-2V4SA
total relays 20 or 36 20 or 36 10 14 14 24 N/A N/A N/A
on/off relays 12 or 24 12 or 24 8 10 10 12 2 3 4
Actuator outputs (open & close) 4 or 6 4 or 6 1 2 2 6 1 1 1
Heat Stages 6 8 2 2 3 4 2 2 2
Brooder Stages 1 N/A 1 1 1 1 N/A N/A N/A
Fan Stages 12 12 8 8 8 N/A 4 5 6
Variable Stages 2 0 2 2 2 N/A 2 2 2
tunnel Stages 2 2 N/A 1 N/A N/A N/A N/A N/A
natural Stages 2 2 N/A N/A 2 6 N/A N/A N/A
inlet Stages 2 2 1 1 1 N/A 1 1 1
chimney Stages N/A N/A N/A N/A N/A 2 N/A N/A N/A
Stir Fan Stages 1 N/A 1 1 1 2 N/A N/A N/A
clock outputs 2 2 2 2 2 2 N/A N/A N/A
mist Stages 1 1 N/A N/A N/A N/A 1 1 1
cooling Stages 1 1 1 1 1 1 N/A N/A N/A
Soaking Stages 1 N/A 1 1 1 1 1 1 1
Light outputs 1 1 N/A N/A N/A N/A N/A N/A N/A
Feeder outputs 2 4 N/A N/A N/A 4 N/A N/A N/A
Back up relay output 1 1 1 1 1 N/A N/A N/A N/A
0-10 Volt outputs** 2 2 2 2 2 2 1 1 1